CUCW-N142 Unitized Curtain Wall

CUCW-N142 Unitized Curtain Wall

Model No. CUCW-N142 is a self-designed, tested, and certificated unitized curtain wall system by CAS team. It is a cost efficient and performance unitized curtain wall, which combines minimal aesthetics with structural stability. Its structural silicone glazing construction offers maximum transparency at the external surface of the facade. Modular units, including glazing panes, are prefabricated in workshop conditions and this results in a fast and economic installation with minimum manpower and tooling requirements. This construction mode, renders CUCW-N142 an ideal system for high rise buildings,where meeting demanding deadlines is a prerequisite.

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CUCW-N142 Unitized Curtain Wall

System Unitized Curtain Wall(Non-Thermal Break)
Model No. CUCW-N142
Material Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/King/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6/6061-T6(Brackets)
Thermal Profile Non-Thermal Break
Standards In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customziation Available



Data of CUCW-N142 Unitized Curtain Wall

Testing Data of CUCW-N142 Unitized Curtain Wall

Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.46kpa No separation, plastic deformations, or deleteriousness was observed.
-1.90kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +438kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 219-438-219 (Pa) There were no leaks.
292-584-292 (Pa)
438-876-438 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Walls)(Clause 8.3 of AS/NZS 4284:2008) +1.46kpa During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-1.90kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-150Pa The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +438Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 219-438-219 (Pa) There were no leaks.
292-584-292 (Pa)
438-876-438 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wells) (Clause 8.8 of AS/NZS 4284:2008) +2.26kpa No collapse of the test specimen was observed under the specified pressure.
-2.94kpa
Seal Degradation Test(Clause 8.10 of AS/NZS 4284:2008) 219-438-219 (Pa) No water leakage was observed.
292-584-292 (Pa)
438-876-438 (Pa)


Thermal Data of CUCW-N142 Unitized Curtain Wall

NFRC Procedures NFRC100SB, NFRC200-2010, and NFRC500-2010
Software Tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Panel Dimension 1505mm Wide 2945mm High
Frame Painted Aluminum
Panel U-value 2.765W/m2k
Visible Light Transmission 0.246
SHGC 0.179


Frame Data of CUCW-N142 Unitized Curtain Wall

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.0580 0.0860 4.1858 1.1968
Left Jamb 0.1270 0.1660 14.8377 1.6873
Right Jamb 0.1270 0.1660 23.7685 1.9897
Sill 0.3280 0.0860 5.7542 1.5668


Glass Data of CUCW-N142 Unitized Curtain Wall

Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
29 19 15 0.19 0.22 1.55 1.54 36


Benefit of CUCW-N142 Unitized Curtain Wall

  • Guaranteed waterproofness & airtightness

  • Great quality control from factory

  • Lower on-site installation cost

  • Shorter project schedule

  • Enhancement of natural light

  • Increased static robustness, even in extreme natural phenomena

  • Minimum after sales service & maintaining

  • Increased comfort level


Configuration of CUCW-N142 Unitized Curtain Wall