CSCW-N180 Stick Curtain Wall

CSCW-N180 Stick Curtain Wall

Stick curtain wall CSCW-N180 is an efficient and reliable curtain wall system with 80mm width profile sightline. Compare to unitized curtain wall, it is flexible for different construction condition and structures, and offer a competitive product cost. 

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CSCW-N180 Stick Curtain Wall

System Stick Curtain Wall (Non-Thermal Break)
Model No. CSCW-N180
Material Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro (Formerly PPG) /Pilkington/Xinyi(SYG)/Yaopi (SYP) /Fuyao/Southglass (SG) /Kibing/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6/6061-T6 (Brackets)
Thermal Profile Non-Thermal Break
Standards In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customization Available




Data of CSCW-N180 Stick Curtain Wall

Testing Data of CSCW-N180 Stick Curtain Wall


Design Wind Pressure Wsls=+1.61KPA/-2.09KAP, Wuls=+2.49KPA/-3.23KPA
Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.61kpa No separation, plastic deformations or deleterious was observed.
-2.09kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +482kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 241-482-241 (Pa) There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) +1.61kpa During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-2.09kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-165Pa The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +482Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 241-482-241 (Pa) There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) +2.49kpa No collapse of the test specimen was observed under the specified pressure.
-3.23kpa
Seal Degradation Test(Clause 8.10 of AS/NZS 4284:2008) 241-482-241 (Pa) No water leakage was observed.
321-642-321 (Pa)
482-964-482 (Pa)



Thermal Data of CSCW-N180 Stick Curtain Wall

NFRC Procedures NFRC100SB, NFRC200-2010, and NFRC500-2010
Software Tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Panel Dimension 1705mm Wide 3245mm High
Frame Painted Aluminum
Panel U-value 3.041W/m2k
Visible Light Transmission 0.271
SHGC 0.197


Frame Data of CSCW-N180 Stick Curtain Wall

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.0638 0.0946 4.60438 1.31648
Left Jamb 0.1397 0.1826 16.32147 1.85603
Right Jamb 0.1397 0.1826 26.14535 2.18867
Sill 0.3608 0.0946 6.32962 1.72348


Glass Data of CSCW-N180 Stick Curtain Wall

Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
31.9 20.9 16.5 0.209 0.242 1.705 1.694 39.6


Benefit of CSCW-N180 Stick Curtain Wall

  •  Certified performances in terms of air, water tightness and wind pressure.

  •  Flexible for on-site installation

  •  Cost efficient product compare to competition

  •  Vast alternatives in custom solutions tailor made to the building

  •  Enhancement of natural light

  •  Increased static robustness, even in extreme natural phenomena

  •  Minimum after sales service & maintaining

  •  Increased comfort level