CHD-TB85 Hinged Door (Thermal Break)

CHD-TB85 Hinged Door (Thermal Break)

Hinged door CHD-TB85, is an entrance door with high-quality standards. The system includes thermal break profiles with a modern design for totally aligned constructions that offer high functionality. Offering many infill options including aluminum or glass panels, it satisfies the demands of thermal insulation and high-security level.

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CHD-TB85 Hinged Door (Thermal Break)

System Swing Door(Thermal-Break)
Model No. CHD-TB85
Material Aluminum Alloy/Glass
Hardware Chinese top brand(Kin Long)/Germany brand
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6
Thermal Profile Thermal Break
Standards In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customization Available



Data of CHD-TB85 Hinged Door (Thermal Break)

Testing Data of CHD-TB85 Hinged Door (Thermal Break)

Test Pressure Results
Open and Close Operable Sash Test (AS 2047 & AS/NZS 4420.1-2016) -- No damage was observed after the test.
Preloading (AS 2047 & AS/NZS 4420.1-2016) +0.81kPa
-0.85kPa
No separation, plastic deformations or deleterious was observed.
Structural Test at Serviceability Limit State  Wind Pressure (Wsls) (AS2047 & AS/NZS 4420.1-2016) +1.62kPa
-1.69kPa
No glass breakage, collapse and permanent deformation was observed. Deflections of mullions and transomes as well as glass panel were within the allowable deflection limits.
Operating Force Test (AS 2047 & AS/NZS 4420.1-2016) -- The operating force of the specimen was within the allowable value.
Air Infiltration Test (AS 2047 & AS/NZS 4420.1-2016) +150Pa
-150Pa
The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Pressure (AS 2047 & AS/NZS 4420. 1-2016) +486Pa No water leakage was observed.
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (AS 2047 & AS/NZS 4420.1-2016) +2.50kpa
-2.60kpa
There was no collapse of the test sample.


Thermal Data of CHD-TB85 Hinged Door (Thermal Break)

NFRC procedures NFRC100SB, NFRC200-2010 and NFRC500-2010
Software tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6 single silver low-e CAVS S1 on Clear #2 + 12Ar + 5/1.52PVB/5 Clear
Panel Dimension 1070mm Wide 2440mm High
Frame Painted Aluminum
Panel U-value 3.906W/m2k
Visible Light Transmission 0.394
SHGC 0.34
Condensation Resistant 28.4


Frame Data of CHD-TB85 Hinged Door (Thermal Break)

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.1840 0.0370 6.1182 2.1869
Left Jamb 0.4750 0.1300 6.0585 2.1841
Right Jamb 0.4750 0.1300 6.1144 2.1880
Sill 0.0960 0.0370 10.0888 2.2422


Glass Data of CHD-TB85 Hinged Door (Thermal Break)

Glass Data: 6mm HS (CAVS S1)#2 +12Ar +6-T-HST
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
72 12 12 0.55 0.63 1.55 1.54 36


Benefit of CHD-TB85 Hinged Door (Thermal Break)

  •  High-security level

  •  High energy savings due to the high energy efficiency of the system

  •  High level of sound insulation

  •  Ease of use and high functionality

  •  Modern design

  •  High quality with certified performances

  •  Increased static loads and functionality in case of severe weather conditions

  •  Entrance doors with ease of access according to specifications for people with special needs