CHD-TB85 Hinged Door (Thermal Break)
Hinged door CHD-TB85, is an entrance door with high-quality standards. The system includes thermal break profiles with a modern design for totally aligned constructions that offer high functionality. Offering many infill options including aluminum or glass panels, it satisfies the demands of thermal insulation and high-security level.
- Overview
- Data
- Benefit
- Configuration
Overview of CHD-TB85 Hinged Door (Thermal Break)
| System | Swing Door(Thermal-Break) |
| Model No. | CHD-TB85 |
| Material | Aluminum Alloy/Glass |
| Hardware | Chinese top brand(Kin Long)/Germany brand |
| Glass Type | Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
| Cooperated Glass Brand | Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass |
| Surface Treatment | Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
| Profile Brand | 6063-T5/6063-T6 |
| Thermal Profile | Thermal Break |
| Standards | In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
| Application | Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
| System Customization | Available |
Data of CHD-TB85 Hinged Door (Thermal Break)
Testing Data of CHD-TB85 Hinged Door (Thermal Break)
| Test | Pressure | Results |
| Open and Close Operable Sash Test (AS 2047 & AS/NZS 4420.1-2016) | -- | No damage was observed after the test. |
| Preloading (AS 2047 & AS/NZS 4420.1-2016) |
+0.81kPa -0.85kPa |
No separation, plastic deformations or deleterious was observed. |
| Structural Test at Serviceability Limit State Wind Pressure (Wsls) (AS2047 & AS/NZS 4420.1-2016) |
+1.62kPa -1.69kPa |
No glass breakage, collapse and permanent deformation was observed. Deflections of mullions and transomes as well as glass panel were within the allowable deflection limits. |
| Operating Force Test (AS 2047 & AS/NZS 4420.1-2016) | -- | The operating force of the specimen was within the allowable value. |
| Air Infiltration Test (AS 2047 & AS/NZS 4420.1-2016) |
+150Pa -150Pa |
The rate of air leakage of the specimen was within the allowable values. |
| Water Penetration Test under Static Pressure (AS 2047 & AS/NZS 4420. 1-2016) | +486Pa | No water leakage was observed. |
| Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (AS 2047 & AS/NZS 4420.1-2016) |
+2.50kpa -2.60kpa |
There was no collapse of the test sample. |
Thermal Data of CHD-TB85 Hinged Door (Thermal Break)
| NFRC procedures | NFRC100SB, NFRC200-2010 and NFRC500-2010 |
| Software tools | THERM 7.4.3.0 and WINDOW 7.4.6.0 |
| Configuration | 6 single silver low-e CAVS S1 on Clear #2 + 12Ar + 5/1.52PVB/5 Clear |
| Panel Dimension | 1070mm Wide 2440mm High |
| Frame | Painted Aluminum |
| Panel U-value | 3.906W/m2k |
| Visible Light Transmission | 0.394 |
| SHGC | 0.34 |
| Condensation Resistant | 28.4 |
Frame Data of CHD-TB85 Hinged Door (Thermal Break)
| Parts Location | Frame Area/m2 | Edge Area/m2 |
U-Value(Frame) W/m2k |
U-Value(Edge) W/m2k |
| Header | 0.1840 | 0.0370 | 6.1182 | 2.1869 |
| Left Jamb | 0.4750 | 0.1300 | 6.0585 | 2.1841 |
| Right Jamb | 0.4750 | 0.1300 | 6.1144 | 2.1880 |
| Sill | 0.0960 | 0.0370 | 10.0888 | 2.2422 |
Glass Data of CHD-TB85 Hinged Door (Thermal Break)
| Glass Data: 6mm HS (CAVS S1)#2 +12Ar +6-T-HST | |||||||
| Visible Light | SHGC | SC |
NFRC U-value W/m3k(Argon) |
STC | |||
| T% | R-out% | R-in% | Winter | Summer | |||
| 72 | 12 | 12 | 0.55 | 0.63 | 1.55 | 1.54 | 36 |
Benefit of CHD-TB85 Hinged Door (Thermal Break)
-
High-security level
-
High energy savings due to the high energy efficiency of the system
-
High level of sound insulation
-
Ease of use and high functionality
-
Modern design
-
High quality with certified performances
-
Increased static loads and functionality in case of severe weather conditions
-
Entrance doors with ease of access according to specifications for people with special needs