CHD-TB85HT Hinged Door (Thermal Break)
Hinged door CHD-TB85HT, is a similar double hinged door system to CHD-TB85. Due to its specially designed profiles, profiles can be hidden underground and make a flat surface. Owning a great performance in thermal insulation with its thermal profiles, it also offers a reliable waterproof and water draining ability.
- Overview
- Data
- Benefit
- Configuration
Overview of CHD-TB85HT Hinged Door (Thermal Break)
System | Swing Door (Thermal Break) |
Model No. | CHD-TB85HT |
Material | Aluminum Alloy/Glass |
Hardware | Chinese top brand(Kin Long)/Germany brand |
Glass Type | Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand | Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass |
Surface Treatment | Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand | 6063-T5/6063-T6 |
Thermal Profile | Thermal Break |
Standards | In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application | Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customization | Available |
Data of CHD-TB85HT Hinged Door (Thermal Break)
Testing Data of CHD-TB85HT Hinged Door (Thermal Break)
Test | Pressure | Results |
Open and Close Operable Sash Test (AS 2047-2014 & AS/NZS 4420.1-2016) | -- | No damage was observed after the test. |
Preloading (AS 2047-2014 & AS/NZS 4420.1-2016) |
+0.81kPa -0.85kPa |
No separation, plastic deformations or deleterious was observed. |
Structural Test at Serviceability Limit State Wind Pressure (Wsls) (AS2047-2014 & AS/NZS 4420.1-2016) |
+1.62kPa -1.62kPa |
No glass breakage, collapse and permanent deformation was observed. Deflections of mullions and transomes as well as glass panel were within the allowable deflection limits. |
Operating Force Test (AS 2047-2014 & AS/NZS 4420.1-2016) | -- | The operating force of the specimen was within the allowable value. |
Air Infiltration Test (AS 2047-2014 & AS/NZS 4420.1-2016) |
+150Pa -150Pa |
The rate of air leakage of the specimen was within the allowable values. |
Water Penetration Test under Static Pressure (AS 2047-2014 & AS/NZS 4420. 1-2016) | +486Pa | No water leakage was observed. |
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (AS 2047-2014 & AS/NZS 4420.1-2016) |
+2.50kpa -2.60kpa |
There was no collapse of the test sample. |
Thermal Data of CHD-TB85HT Hinged Door (Thermal Break)
NFRC Procedures | NFRC100SB, NFRC200-2010 and NFRC500-2010 |
Software Tools | THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration | 6 single silver Low-E CAVS S1 on Clear #2 + 12Ar + 5/1.52PVB/5 Clear |
Panel Dimension | 2000mm Wide 2440mm High |
Frame | Painted Aluminum |
Panel U-value | 3.481W/m2k |
Visible Light Transmission | 0.45 |
SHGC | 0.376 |
Condensation Resistant | 30.5 |
Frame Data of CHD-TB85HT Hinged Door (Thermal Break)
Parts Location | Frame Area/m2 | Edge Area/m2 |
U-Value(Frame) W/m2k |
U-Value(Edge) W/m2k |
Left Header | 0.1910 | 0.0420 | 6.1182 | 2.1869 |
Left Jamb | 0.4750 | 0.1300 | 6.0585 | 2.1841 |
Right Header | 0.1910 | 0.0420 | 6.1182 | 2.1869 |
Mullion | 0.3980 | 0.2530 | 4.8335 | 2.1265 |
Right Jamb | 0.4750 | 0.1300 | 6.1144 | 2.1880 |
Left Sill | 0.0990 | 0.0420 | 10.0888 | 2.2422 |
Right Sill | 0.0990 | 0.0420 | 10.0888 | 2.2422 |
Glass Data of CHD-TB85HT Hinged Door (Thermal Break)
Glass Data: 6mm HS (CAVS S1)#2 +12Ar +6-T-HST | |||||||
Visible Light | SHGC | SC |
NFRC U-value W/m3k(Argon) |
STC | |||
T% | R-out% | R-in% | Winter | Summer | |||
72 | 12 | 12 | 0.55 | 0.63 | 1.55 | 1.54 | 36 |
Benefit of CHD-TB85HT Hinged Door (Thermal Break)
-
Hidden aluminum profiles
-
Great performance in waterproofness and water draining
-
High energy savings due to the high energy efficiency of the system
-
High level of sound insulation
-
Modern design
-
High quality with certified performances
-
Increased static loads and functionality in case of severe weather conditions
-
Entrance doors with ease of access according to specifications for people with special needs