CSD-N150 Sliding Door

CSD-N150 Sliding Door

CSD-N150 is a non-insulated system for sliding doors with a modern flat design. The system meets a wide range of needs using common profiles for the construction of simple sliding typologies. Ideal solution for large spans and warmer climates.

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CSD-N150 Sliding Door

System Sliding Door(Non-Thermal Break)
Model No. CSD-N150
Material Aluminum Alloy/Glass
Hardware Chinese top brand(Kin Long)/Germany brand
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6
Thermal Profile Non-Thermal Break
Standards In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customization Available



Data of CSD-N150 Sliding Door

Testing Data of CSD-N150 Sliding Door

Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.81kpa
-2.68kpa
No separation, plastic deformations or deleterious was observed.
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +543kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 272-300-272 (Pa)
362-724-362 (Pa)
543-1086-543 (Pa)
There were no leaks.
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) +1.81kpa
-2.68kpa
No glass breakage, no collapse and permanent deformation were observed. Deflections of mullions and transoms as well as glass panel were within the allowable deflection limits.
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-150Pa The rate of air leakage of the specimen was within the allowable values.
Operating force test (AS 2047-2014, Clause 2.3.2.4) -- The operating force of the specimen was within allowable value.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +543Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 272-300-272 (Pa)
362-724-362 (Pa)
543-1086-543 (Pa)
There were no leaks.
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) +2.79kpa
-4.15kpa
No collapse of the test specimen was observed under the specified pressure.

Thermal Data of CSD-N150 Sliding Door

NFRC procedures NFRC100SB, NFRC200-2010 and NFRC500-2010
Software tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6mm LB13-45HS+12A+6mm Clear HST
Panel Dimension 1900mm Wide x 2750mm High
Frame Painted Aluminum
Panel U-value 3.771W/m2k
Visible Light Transmission 0.28
Condensation Resistant 19.1


Frame Data of CSD-N150 Sliding Door

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Left Header 0.1210 0.0490 7.9102 2.2952
Left Jamb 0.3260 0.1540 11.1172 2.0309
Right Header 0.1180 0.0490 9.5335 2.1194
Mullion 0.1170 0.3000 22.6254 1.9365
Right Jamb 0.3410 0.1540 8.7912 2.1402
Left Sill 0.1100 0.0490 7.7840 2.2897
Right Sill 0.1130 0.0490 11.4681 2.1552


Glass Data of CSD-N150 Sliding Door

Glass Data: 6mm LB13-45HS+12A+6mm Clear HST
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
40 20 13
0.26 1.43 1.36 36


Benefit of CSD-N150 Sliding Door

  • High security level

  • Modern design

  • Slim lines for sliding typologies with maximum visibility

  • Great ease of use and high functionality

  • Increased static loads and functionality in case of severe weather conditions

  • Exceptional quality with certified performances

  • Exceptional sound insulation

  • Ideal for wide spans