CCW-N50OZD Casement Window
Casement Window CAW-N50OZD is a non thermal breaking window system which is specialized at air ventilation for personal and public area. Compatible with quality EPDM gasket, it can obtain a supreme airtightness and watertightness.
- Overview
- Data
- Benefit
- Configuration
Overview of CCW-N50OZD Casement Window
System | Casement Window(Non-Thermal Break) |
Model No. | CCW-N50OZD |
Material | Aluminum Alloy/Glass |
Hardware | Chinese top brand(Kin Long)/Germany brand |
Glass Type | Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand | Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass |
Surface Treatment | Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand | 6063-T5/6063-T6 |
Thermal Profile | Non-Thermal Break |
Standards | In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application | Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customization | Available |
Data of CCW-N50OZD Casement Window
Testing Data of CCW-N50OZD Casement Window
Test | Pressure | Results |
Preloading(Clause 8.2.2 of AS/NZS4284:2008) | +2.06kpa | No separation, plastic deformations or deleterious was observed |
-2.06kpa | ||
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) | +774kPa | No water leakage was observed. |
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) | 387-774-387 (Pa) | No water leakage was observed. |
516-1032-516 (Pa) | ||
774-1548-774 (Pa) | ||
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) | +2.06kpa | During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits. |
-2.06kpa | ||
Operating force test (AS 2047-2014) | -- | The operating force was within the allowable value. |
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) | +/-150Pa | The rate of air leakage of the specimen was within the allowable values. |
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) | +774Pa | No water leakage was observed. |
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) | 387-774-387 (Pa) | No water leakage was observed. |
516-1032-516 (Pa) | ||
774-1548-774 (Pa) | ||
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) | +3.20kpa | No collapse of the test specimen was observed under the specified pressure. |
-3.20kpa |
Thermal Data of CCW-N50OZD Casement Window
NFRC Procedures | NFRC100SB, NFRC200-2010 and NFRC500-2010 |
Software Tools | THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration | 6mm Clear(CLR-TDE52C) + 12mm ARGON + 6mm Clear |
Panel Dimension | 1100mm Wide x 1100mm High |
Frame | Painted Aluminum |
Panel U-value | 2.369W/m2k |
Visible Light Transmission | 0.302 |
SHGC | 0.149 |
Frame Data of CCW-N50OZD Casement Window
Parts Location | Frame Area/m2 | Edge Area/m2 |
U-Value(Frame) W/m2k |
U-Value(Edge) W/m2k |
Header | 0.1264 | 0.0376 | 9.8209 | 1.7751 |
Upper Left Jamb | 0.1118 | 0.0700 | 4.6895 | 1.5839 |
Upper Right Jamb | 0.1118 | 0.0700 | 4.6895 | 1.5839 |
Mullion | 0.0721 | 0.0732 | 5.2684 | 1.5885 |
Lower Left Jamb | 0.0470 | 0.0773 | 7.2276 | 1.6265 |
Lower Right Jamb | 0.0470 | 0.0773 | 7.2276 | 1.6265 |
Sill | 0.0523 | 0.0439 | 17.1106 | 2.2366 |
Glass Data of CCW-N50OZD Casement Window
Glass Data: 6mm LB13-45#2HS+12AR+6mm Clear HST | |||||||
Visible Light | SHGC | SC |
NFRC U-value W/m3k(Argon) |
STC | |||
T% | R-out% | R-in% | Winter | Summer | |||
51.9 | 23 | 15 |
|
0.271 | 1.368 | 1.294 | 36 |
Benefit of CCW-N50OZD Casement Window
-
Aluminum profile width: 50mm, T=1.6mm European - standard notch.Applicable to Fixed Windows, Awning Windows, Casement Windows, Horizontal Pivoting Windows. The extra-long frame can be combined with pipe-type installation & Australian installation (waterproof rubber strip at the bottom).
-
Standard configuration: 6mm+12A+6mm insulating glass. Other configurations can be equipped with the same standard thickness, such as DGU, laminated glass, etc.
-
With a total 89mm sightline profile, it provides better natural light transmittance and still keeps good heat insulation performance.