CCW-N101BE Casement Window

CCW-N101BE Casement Window

CCW-N101BE is a commercial aluminum casement window system. Compatible with quality hardware and performance glass, it will be the most durable window system for commercial area, such as office, mall...


  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CCW-N101BE Casement Window

Testing Data of CUCW-N142 Unitized Curtain Wall

Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.46kpa No separation, plastic deformations, or deleteriousness was observed.
-1.90kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +438kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 219-438-219 (Pa) There were no leaks.
292-584-292 (Pa)
438-876-438 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Walls)(Clause 8.3 of AS/NZS 4284:2008) +1.46kpa During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-1.90kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-150Pa The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +438Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 219-438-219 (Pa) There were no leaks.
292-584-292 (Pa)
438-876-438 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wells) (Clause 8.8 of AS/NZS 4284:2008) +2.26kpa No collapse of the test specimen was observed under the specified pressure.
-2.94kpa
Seal Degradation Test(Clause 8.10 of AS/NZS 4284:2008) 219-438-219 (Pa) No water leakage was observed.
292-584-292 (Pa)
438-876-438 (Pa)


Thermal Data of CUCW-N142 Unitized Curtain Wall

NFRC Procedures NFRC100SB, NFRC200-2010, and NFRC500-2010
Software Tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Panel Dimension 1505mm Wide 2945mm High
Frame Painted Aluminum
Panel U-value 2.765W/m2k
Visible Light Transmission 0.246
SHGC 0.179


Frame Data of CUCW-N142 Unitized Curtain Wall

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.0580 0.0860 4.1858 1.1968
Left Jamb 0.1270 0.1660 14.8377 1.6873
Right Jamb 0.1270 0.1660 23.7685 1.9897
Sill 0.3280 0.0860 5.7542 1.5668


Glass Data of CUCW-N142 Unitized Curtain Wall

Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
29 19 15 0.19 0.22 1.55 1.54 36



Data of CCW-N101BE Casement Window

Testing Data of CCW-N101BE Casement Window

Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +2.06kpa No separation, plastic deformations or deleterious was observed
-2.06kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +774kPa No water leakage was observed.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 387-774-387 (Pa) No water leakage was observed.
516-1032-516 (Pa)
774-1548-774 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) +2.06kpa During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-2.06kpa
Operating force test (AS 2047-2014) -- The operating force was within the allowable value.
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-150Pa The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +774Pa No water leakage was observed.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 387-774-387 (Pa) No water leakage was observed.
516-1032-516 (Pa)
774-1548-774 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) +3.20kpa No collapse of the test specimen was observed under the specified pressure.
-3.20kpa


Thermal Data of CCW-N101BE Casement Window

NFRC Procedures NFRC100SB, NFRC200-2010 and NFRC500-2010
Software Tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6mm Clear(CLR-TDE52C) + 12mm ARGON + 6mm Clear
Panel Dimension 1100mm Wide x 1100mm High
Frame Painted Aluminum
Panel U-value 2.136W/m2k
Visible Light Transmission 0.302
SHGC 0.155


Frame Data of CCW-N101BE Casement Window

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.1340 0.0399 9.4281 1.7041
Upper Left Jamb 0.1185 0.0742 4.5019 1.5205
Upper Right Jamb 0.1185 0.0742 4.5019 1.5205
Mullion 0.0764 0.0775 5.0577 1.5250
Lower Left Jamb 0.0498 0.0820 6.9385 1.5614
Lower Right Jamb 0.0498 0.0820 6.9385 1.5614
Sill 0.0554 0.0465 16.4261 2.1471


Glass Data of CCW-N101BE Casement Window

Glass Data: 6mm LB13-45#2HS+12AR+6mm Clear HST
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
51.9 23 15
0.271 1.368 1.294 36


Benefit of CCW-N101BE Casement Window

  • Aluminum profile width: 101.6mm, T=2.0mm. Applicable to Fixed Windows, Awning Windows, Casement Window. The extra-long frame can be combined with pipe-type installation and inflection point-type installation.

  • Standard configuration: 6+12A+6mm insulated glass, or other DGU/Laminated glass with the same thickness.

  • The anti-insect screen is optional, which is easy to install or disassemble with bare hands.  The "hiding inside" design perfectly merges the screen with the profiles, making a delicate appearance.

  • Adjustable opening angle with manual window opener.


Configuration of CCW-N101BE Casement Window

Blog

Contact Us

Welcome your presence, you can send us an email, we will get in touch with you within 24 hours.