CWW-TB150 Window Wall (Thermal Insulation)

CWW-TB150 Window Wall (Thermal Insulation)

Window wall CWW-N15 is a system in great performance of thermal insulation, with high energy efficient thermal break aluminum profile mullions and transoms. It totally offers quality constructions in affordable prices and fully meets all stability and safety requirements.

  • Overview
  • Data
  • Benefit
  • Configuration

Overview of CWW-TB150 Window Wall (Thermal Insulation)

System Window Wall(Thermal Break)
Model No. CWW-TB150
Material Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet
Hardware Chinese top brand(Kin Long)/Germany brand
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6/6061-T5/6061-T6
Themral Profile Non-Thermal Break/Thermal Break
Standards In Complianca With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customziation Available



Data of CWW-TB150 Window Wall (Thermal Insulation)

Testing Data of CWW-TB150 Window Wall

Design Wind Pressure Wsls=+1.61KPA/-2.09KAP, Wuls=+2.49KPA/-3.23KPA
Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.61kpa No separation, plastic deformations or deleterious was observed.
-2.09kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +482kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 241-482-241 (Pa) There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) +1.61kpa During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits.
-2.09kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-165Pa The rate of air leakage of the specimen was within the allowable values.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +482Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 241-482-241 (Pa) There were no leaks.
321-642-321 (Pa)
482-964-482 (Pa)
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) +2.49kpa No collapse of the test specimen was observed under the specified pressure.
-3.23kpa
Seal Degradation Test(Clause 8.10 of AS/NZS 4284:2008) 241-482-241 (Pa) No water leakage was observed.
321-642-321 (Pa)
482-964-482 (Pa)


Thermal Data of CWW-TB150 Window Wall

NFRC Procedures NFRC100SB, NFRC200-2010 and NFRC500-2010
Software Tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6mm HS (CAVS S1)#2 +12Ar +6-T-HST
Panel Dimension 2640mm Wide 6890mm High
Frame Painted Aluminum
Panel U-value 2.293W/m2k
Visible Light Transmission 0.69
SHGC 0.547


Frame Data of CWW-TB150 Window Wall

Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame)
W/m2k
U-Value(Edge)
W/m2k
Header 0.0450 0.0640 11.1056 1.9779
Left Jamb 0.1040 0.1580 6.8634 1.8595
Right Jamb 0.1040 0.1580 6.8771 1.8573
Sill 0.0500 0.0640 12.7728 1.9112


Glass Data of CWW-TB150 Window Wall

Glass Data: mm HS (CAVS S1)#2 +12Ar +6-T-HST
Visible Light SHGC SC NFRC U-value
W/m3k(Argon)
STC
T% R-out% R-in% Winter Summer
72 12 12 0.55 0.63 1.55 1.54 36


Benefit of CWW-TB150 Window Wall (Thermal Insulation)

  • High Energy Efficiency

  • Enhancement of Natural Light

  • Being up to complicated facade design requirements

  • Faster installation speed

  • A expanded view for daily routine

  • Ability to design custom solutions tailor made to the building

  • Minimum after sales service & maintaining

  • Increased comfort level


Configuration of CWW-TB150 Window Wall (Thermal Insulation)